EPS Insulation Fire Testing

In April 2018, tests to the EN 13823 and EN 11925-2 standards were carried out by material testing experts Exova Warringtonfire, to determine the classification of our Expanded Polystyrene Insulation (FRA).

(This covers both our sheet insulation and loose-fill cavity wall insulation.)


Samples of different depths of expanded polystyrene containing flame retardant additive were tested, achieving the following result: Euroclass C-s1-d0* (on depths of 20mm-200mm)

Fire Testing in action, in Exova's laboratory:

Please accept marketing cookies to watch this video.

Click HERE and HERE to view the Fire Test Reports in full.


*********************

Safety Data Sheet

Technical Data Sheet - When Containing a Fire Retardant Additive

*********************

Polystyrene Insulation Guidance

Care must be taken when installing PVC cables, to ensure that they do not come into contact with polystyrene insulation.

A chemical reaction takes place between the PVC sheath and the polystyrene, resulting in a migration of polymers with the cable, known as 'marring'.